Description
Product Name: Intelligent Flow Totalizer / Flow Integrator Controller
Model: AEM290
Panel Dimensions: 160 × 80 mm
Display Type: 128 × 64 Backlit Graphic LCD
Signal Compatibility: 4–20mA, 0–10mA, Pulse, Frequency, Pt100 and Thermocouple
Communication Interfaces: RS232, RS485 and Ethernet
Customization: OEM Configuration Available
Minimum Order Quantity: 1 Unit
Product Overview
The AEM290 Intelligent Flow Totalizer is a versatile industrial monitoring and control instrument engineered for precise flow measurement, accumulated volume calculation, energy monitoring and process data management.
Developed with microprocessor-based digital technology, this programmable flow integrator receives signals from compatible flowmeters, temperature sensors and pressure transmitters. It processes measurement data and presents key operating parameters through an easy-to-read LCD interface.
The instrument is suitable for monitoring liquid flow, gas consumption, saturated steam, superheated steam and thermal energy systems. Integrated temperature and pressure compensation functions support more accurate flow calculations under varying operating conditions.
In addition to continuous measurement, the AEM290 provides configurable alarm outputs, batch control capabilities, data recording and communication functions. It can be incorporated into centralized monitoring systems to support industrial automation, utility management and energy accounting.
With multiple signal input options, a flexible communication architecture and programmable operating parameters, this flow totalizer offers a practical solution for OEM manufacturers, automation contractors, system integrators and industrial equipment suppliers.

Key Features and Operational Benefits
1. Comprehensive Flow and Energy Monitoring
The AEM290 combines instantaneous flow indication, cumulative flow measurement and energy calculation in a single digital instrument.
Depending on the selected configuration and connected sensors, operators can monitor flow rate, total consumption, temperature, pressure, density, heat enthalpy and other process variables.
This integrated approach simplifies monitoring and reduces the need for multiple standalone display instruments.
2. High-Visibility Digital Display
Equipped with a 128 × 64 dot-matrix LCD featuring backlight illumination, the instrument provides clear presentation of measurement values and operating information.
Its automatic cyclic display function enables users to review different parameters without repeatedly navigating through menus.
Displayable information includes:
-
Instantaneous and accumulated flow
-
Thermal energy and power
-
Medium temperature and pressure
-
Density and enthalpy
-
Differential pressure
-
Input current and frequency
-
Date, time and alarm conditions
3. Broad Sensor and Signal Compatibility
The controller accepts several commonly used industrial signals, including analog current inputs, pulse signals, resistance temperature detectors and thermocouples.
This makes it adaptable to a wide range of flow measurement equipment and temperature or pressure transmitters.
Available signal options help simplify integration with new installations and existing process control systems.
4. Temperature and Pressure Compensation
For applications involving compressible gases or steam, changes in temperature and pressure may influence measurement results.
The AEM290 supports compensation calculations using relevant operating parameters, helping provide corrected flow measurements for gas and steam monitoring.
This function is particularly useful in industrial energy consumption measurement and utility distribution systems.
5. Programmable Batch Measurement and Control
The instrument supports quantitative control operations for applications requiring preset flow quantities or controlled material transfer.
Start, stop and reset functions allow operators to manage measurement cycles according to process requirements.
Optional relay outputs can also be used for configurable upper and lower alarm conditions.
6. Industrial Communication and System Integration
The AEM290 offers communication capabilities designed for connection with computers and industrial monitoring networks.
Supported interface options include RS232, RS485 and Ethernet. Additional communication arrangements may include GPRS, CDMA and broadband network connectivity, depending on system configuration.
These functions facilitate integration into industrial data acquisition, centralized metering and energy management applications.
7. Historical Data Storage and Metering Management
For facilities requiring traceable consumption records, the instrument provides data storage and management functions.
Features include:
-
Daily accumulated value storage for up to 365 days
-
Monthly accumulated value storage for up to 12 months
-
Automatic meter reading at preset intervals
-
Power interruption records
-
Unauthorized operation history queries
-
Real-time and scheduled printing
These capabilities support utility accounting, consumption analysis and routine operational reporting.
8. Secure and Reliable Instrument Design
The controller incorporates a three-level password system to restrict access to important settings.
Its internal electronic design eliminates traditional adjustable potentiometers and encoder switches, improving resistance to vibration and reducing the possibility of mechanical adjustment instability.
Additional protective features include a watchdog reset mechanism, low-voltage reset, self-recovering fuse and short-circuit protection.
Technical Specifications
Measurement Inputs
| Parameter | Specification |
|---|---|
| Analog Current Input | 0–10mA / 4–20mA |
| Input Impedance | ≤250Ω |
| RTD Input | Pt100 |
| Thermocouple Types | K, E, B, J, N, T, S |
| Pulse Input Waveforms | Rectangular, sine and triangular |
| Pulse Signal Amplitude | Greater than 4V |
| Frequency Input Range | 0–10kHz |
| Special Input Requirements | Available upon request |
Output and Communication
| Parameter | Specification |
|---|---|
| Analog Output | DC 0–10mA / DC 4–20mA |
| 0–10mA Output Load | ≤750Ω |
| 4–20mA Output Load | ≤500Ω |
| Communication Interfaces | RS232 / RS485 / Ethernet |
| Baud Rate | 600, 1200, 2400, 4800, 9600bps |
| Serial Data Format | 8 data bits, 1 stop bit, 1 start bit |
| Relay Output | Up to 2 optional alarm relays |
| Relay Rating | AC 220V/3A or DC 24V/6A, resistive load |
| Sensor Supply Output | DC 24V, ≤100mA |
| Alternative Supply Output | DC 12V, ≤200mA |
Measurement and Display Performance
| Parameter | Specification |
|---|---|
| Measurement Accuracy | 0.2% FS ±1 digit or 0.5% FS ±1 digit |
| Frequency Conversion Accuracy | ±1 pulse (LMS), better than 0.2% |
| Flow and Compensation Display Range | -999999 to 999999 |
| Totalized Value Range | 0 to 99999999.9999 |
| LCD Resolution | 128 × 64 pixels |
| Display Technology | Backlit dot-matrix graphic LCD |
| Alarm Types | Flow, temperature and pressure high/low limits |
| Alarm Adjustment | Configurable hysteresis |
| Alarm Indication | LCD and LED indicators |
Power Supply and Environmental Conditions
| Parameter | Specification |
|---|---|
| Standard Power Supply | AC 220V, 50Hz ±2Hz |
| Wide-Range AC Supply Option | AC 80–265V |
| DC Power Option | DC 24V ±1V |
| Alternative AC Option | AC 36V, 50Hz ±2Hz |
| Backup Power | 12V, 20Ah |
| Backup Operating Duration | Up to 72 hours |
| Power Consumption | ≤10W |
| Operating Temperature | -20°C to +60°C |
| Relative Humidity | ≤85% RH |
| Installation Environment | Avoid highly corrosive gases |
| Totalizer Data Retention | More than 20 years without power |
Note: Certain power supply, output, communication and control functions depend on the instrument configuration. Confirm the required options before purchasing.
Typical Industrial Applications
Water Supply and Liquid Process Monitoring
Suitable for monitoring liquid flow and cumulative consumption in water distribution, industrial processing, liquid transfer and utility metering applications.
Natural Gas and Industrial Gas Metering
Supports gas flow measurement applications where temperature and pressure compensation are required for improved measurement consistency.
Steam Distribution and Energy Management
Designed for saturated and superheated steam systems, enabling flow accumulation, thermal energy monitoring and consumption recording.
HVAC and Building Utility Management
Can be integrated into centralized heating, cooling and energy monitoring installations to support measurement and operational data collection.
Industrial Automation and Batch Processing
Provides measurement display, preset quantity control and relay alarm functions for various automated process applications.
OEM Equipment and System Integration
Its programmable parameters, multiple input options and communication interfaces make it suitable for incorporation into customized industrial equipment and metering systems.
Data Logging, Printing and Protection Functions
The AEM290 offers additional functions intended for applications requiring continuous monitoring and documented measurement records.
Scheduled Meter Reading: Automatic data capture can be configured to support periodic consumption reporting.
Serial Printer Connection: An RS232 interface allows connection to a compatible serial thermal printer for immediate or timed printouts. Up to eight scheduled printing operations can be configured per day.
Non-Volatile Data Storage: Accumulated measurement data can be maintained for more than 20 years after power interruption.
Operational Security: Multi-level password authorization and operation history records help control access to critical instrument settings.
Automatic Recovery: Internal monitoring and protection features support stable operation during abnormal system conditions.
Frequently Asked Questions
Q1: What is the purpose of an intelligent flow totalizer?
An intelligent flow totalizer is an electronic instrument that processes flow sensor signals to calculate instantaneous flow and accumulated consumption. Depending on the instrument configuration, it may also provide energy calculations, alarms, compensation functions and communication capabilities.
Q2: Can this controller be connected to different flowmeter types?
Yes. The AEM290 supports standard industrial input signals such as 4–20mA, 0–10mA and pulse/frequency inputs. It also accepts Pt100 and several thermocouple signal types, allowing connection to compatible measuring devices.
Q3: Does the instrument support gas and steam flow applications?
Yes. It can be used in various gas and steam measurement systems, including saturated steam and superheated steam applications. Temperature and pressure compensation functions are available for suitable measurement configurations.
Q4: What measurement accuracy can be expected?
The listed instrument accuracy is 0.2% FS ±1 digit or 0.5% FS ±1 digit, depending on the selected specification. Frequency conversion performance is specified as better than 0.2%.
Overall system accuracy also depends on the connected sensors, installation conditions and calibration.
Q5: Is remote monitoring possible?
The controller provides communication interface options including RS485, RS232 and Ethernet. These can be used for connection to compatible host computers or industrial monitoring systems. The applicable communication protocol should be confirmed for the selected configuration.
Q6: Can accumulated flow records be saved during a power failure?
Yes. The instrument features non-volatile storage designed to retain totalized data for more than 20 years without electrical power. It also provides power interruption records for operating history review.
Q7: Can the controller activate an alarm when flow exceeds a preset value?
Yes. Optional relay outputs support configurable high and low alarm limits. Alarm monitoring is available for flow, temperature and pressure, with adjustable hysteresis to help prevent unnecessary switching.
Q8: How are operating parameters configured?
Instrument parameters can be adjusted through the front-panel controls. Password protection is provided to help prevent unauthorized changes. Additional configuration methods depend on the supplied model and interface options.
Q9: Is the instrument suitable for continuous industrial use?
The AEM290 is designed for industrial monitoring applications, with watchdog protection, automatic reset functions, short-circuit protection and non-volatile storage. Its specified ambient operating temperature is -20°C to +60°C.
Q10: What information is needed when requesting an OEM quotation?
To select a suitable configuration, buyers should provide the application medium, sensor signal type, required measurement functions, communication interface, power supply and expected order quantity.